PHYSICS Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Term | Definition |
| CONTROLLING FACTOR OF CONTRAST | KVP IS MAIN CONTROLLING FACTOR (HAS IN DIRECT RELATIONSHIP TO CONTRAST) |
| FILTRATION | BEAM ATTENUATORS (DECREASE SKIN EXPOSURE TO PATIENT) |
| GRIDS TO DENSITY | INCREASE IN GRID RATIO WILL DECREASE |
| RECORDED DETAIL (CAN BE AFFECTED BY) | SID, OID, FOCAL SPOT, & MOTION |
| SID & DETAIL | DIRECTLY PROPORTIONAL (MORE DISTANCE = MORE DETAIL) |
| OID & DETAIL | INDIRECTLY PROPORTIONAL (LESS DISTANCE = MORE DETAIL) LESS MAGNIFICATION |
| DISTORTION TYPES | SHAPE (ELONGATION/FORSHORTENING)OR SIZE DISTORTION(MAGNIFICATION) |
| GREATER SID | LESS MAGNIFICATION (INDIRECT RELATIONSHIP) |
| GREATER OID | GREATER MAGNIFICATION (DIRECT RELATIONSHIP) |
| DENSITY | OVERALL BLACKNESS PRODUCED ON THE IMAGE (A LOT OF DENSITY = DECREASE IN BRIGHTNESS) |
| FACTORS THAT AFFECT DENSITY | MAS, SID, KVP, GRIG, FILTRATION, BEAM RESTRICTION, FILM SCREEN COMBO |
| MAS | AMOUNT OF RADIATION EXPOSURE |
| MAS TO DENSITY | HAS DIRECT PROPORTIONAL (INCREASE IN MAS = INCREASE IN ) |
| DOUBLE MAS = DOUBLE DENSITY | 20 MAS 80 KVP 40 MAS 80 KVP (DOUBLED MAS) |
| MAS TO CONTRAST | HAS NO AFFECT ON MAS |
| KVP | ENERGY |
| KVP TO DENSITY | HAS DIRECT RELATIONSHIP / NOT PROPORTIONAL (DOUBLE DENSITY-INCREASE KVP BY 15%) |
| DOUBLE KVP = 15% INCREASE | 20 MAS 80 KVP 20 MAS 92KVP (DOUBLED DENSITY) |
| CONTROLLING FACTOR OF CONTRAST | KVP IS MAIN CONTROLLING FACTOR (HAS IN DIRECT RELATIONSHIP TO CONTRAST) |
| KVP TO CONTRAST | INCREASE TO KVP = DECREASE TO CONTRAST |
| SID | SOURCE TO IMAGE DISTANCE |
| SID TO CONTRAST | SID HAS NO AFFECT |
| GRID | ELIMINATES SCATTER RADIATION PRIOR TO INTERACTING WITH IR |
| FILTRATION TO DENSITY | FILTRATION INCREASE WILL DECREASE |
| FILTRATION TO LOW ENERGY | ABSORBS LOW ENERGY TO PATIENT BUT NOT GO FOR IMAGE |
| BEAM RESTRICTION | COLLIMATION (LESS AREA FOR PHOTONS TO REACH) |
| INCREASE BEAM RESTRICTION (COLLIMATE SMALLER) | DECREASES FIELD SIZE, DECREASES DENSITY |
| COLLIMATION TO DENSITY | INDIRECT RELATIONSHIP TO DENSITY |
| INCREASE BEAM RESRTICTION | DECREASE SCATTER , INCREASE CONTRAST, DIRECT RELATIONSHIP |
| ANODE HEEL EFFECT | A PHENOMENON IN WHICH THE THE INTENSITY OF THE X-RAY BEAM IS GREATER TOWARDS THE CATHODE SIDE OF THE TUBE. THE VARIATION IN X-RAY INTENSITY ALONG THE LONGITUDINAL TUBE AXIS |
| CONTRAST | DEGREE OF DIFF BETWEEN ADJACENT DENSITIES (RESULT OF TISSUE DIFFERENTIAL ABSORPTION OF THE XRAY PHOTONS) |
| HIGH CONTRAST SHORT SCALE = LOW KVP | RADIOGRAPH WITH FEW DENSITIES BUT GREAT DIFF BETWEEN THEM - HAND, TIB/FIB |
| LOW CONTRAST HIGH SCALE = HIGH KVP | RADIOGRAPH WITH LARGE NUMBER OF DENSITIES WITH LITTLE DIFF AMONG THEM - CHEST, PELVIS |
| CONTRAST IS AFFECTED BY | TISSSUE THICKNESS, DENSITY, EFECTIVE AUTOMIC NUM. |
| QUALITY OF BEAM (CONTRAST) | AFFECTS ATTENUATION WHICH IN RETURN AFFECTS SUBJECT CONTRAST |
| CHEST XRAY HAS HIGH OR LOW CONTRAST | LOW CONTRAST (DIFF TISSUE THICKNESS, AUTOMIC #) |
| ABDOMEN WOULD HAVE HIGH OR LOW CONTRAST | LOW CONTRAST (ORGANS ARE SIMILAR) |
| OID | OBJECT IMAGE DISTANCE (SPACE FROM SUBJECT TO IR) |
| OID TO CONTRAST | IF OID INCREASES, CONTRAST WILL INCREASE BECAUSE OF THE AIR GAP. ROOM FOR THE SCATTER PHOTONS TO DIVERGE |
| KVP FACTS | INCREASE KVP = INCREASE IN DENSITY KVP IS THE SQUARE OF DENSITY INCREASE KVP = DECREASE IN CONTRAST NOTHING TO DETAIL NOTHING TO DISTORTION |
| MAS FACTS | DOUBLE MAS = DOUBLE DENSITY NO AFFECT ON ON CONTRAST NOTHING ON DETAIL NOTHING ON DISTORTION |
| TUBE PART ANGLE | INCREASE ANGLE = DECREASE DENSITY INCREASE ANGLE = DECREASE DETAIL INCREASE ANGLE = INCREASE DISTORTION NOTHING TO CONTRAST |
| FOCAL SPOT SIZE | INCREASE FOCAL SPOT = DECREASE DETAIL NOTHING TO DENSITY NOTHING TO CONTRAST NOTHING TO DISTORTION |
| OID FACTS | INCREASE TO OID = DECREASE TO DENSITY INCREASE TO OID = INCREASE TO CONTRAST INCREASE TO OID = INCREASE TO DISTORTION INCREASE TO OID = DECREASE TO DETAIL |
| SID FACTS | INCREASE SID = DECREASE TO DENSITY INCREASE SID = DECREASE TO DISTORTION INCREASE SID = INCREASE TO DETAIL NOTHING TO CONTRAST |
| BEAM RESTRICTION (COLLIMATION) | INCREASE BEAM RESTRICTION = DECREASE DENSITY INCREASE BEAM RESTRICTION = INCREASE CONTRAST NOTHING ON DETAIL NOTHING ON DISTORTION |
| FILTRATION FCATS | NCREASE FILTRATION = DECREASE CONTRAST INCREASE FILTRATION = DECREASE DENSITY NOTHING ON DISTORTION NOTHING ON DETAIL |
| GRID FACTS | INCREASE GRID = DECREASE DENSITY INCREASE GRID = INCREASE CONTRAST NOTHING TO DETAIL NOHTING TO DISTORTION |
Created by:
CHILLFCTR007