Imaging Final Test

Enter the letter for the matching Answer
incorrect
1.
Larger matrix= smaller pixels=improved sharpness
incorrect
2.
which major technical component of a digital radiography system refers to the collection of X-rays transmitted through the patient
incorrect
3.
Photostimulable phosphors have the property of creating and storing a _____ when exposed to X-rays
incorrect
4.
____ produce(s) lateral spreading of light, which destroys the spatial resolution of the image.
incorrect
5.
______ is a photoconductor that conducts electrons when struck by light or X-ray photons
incorrect
6.
DR is characterized by
incorrect
7.
what does X-ray exposure of the PSP IP create
incorrect
8.
Have a thick phosphor layer, absorbs more radiation, have faster speeds High speeds= low resolution
incorrect
9.
Have thinner layers of phosphor, provide sharper images, used when small detail is critical Slower speed= high resolution
incorrect
10.
reducing KVP using a grid and increasing collimation all reduce the production of scattered radiation
incorrect
11.
Exposure latitude is to conventional radiography as ____ is to DR
incorrect
12.
the exposure indicator number is an
incorrect
13.
grossly overexposed digital images will demonstrate
incorrect
14.
the window width controls
incorrect
15.
the window width
incorrect
16.
CR systems acquire clinical info by
incorrect
17.
the purpose of a LUT is to
incorrect
18.
Four primary steps in CR
incorrect
19.
The digital detector used in CR Imaging is the
incorrect
20.
computerized digital images consists of a ____ of picture elements, each with a video display value or gray shade
A.
Image acquisition Image plate scanning and then erasure Image processing Image display
B.
powdered phosphors
C.
Laser scanning a PSP plate
D.
image contrast
E.
latent image
F.
the use of a reusable receptor
G.
matrix
H.
Dynamic range
I.
Imaging plate
J.
High resolution IPS
K.
apple a predetermined scale of contrast to digital data sets
L.
Latent image
M.
a loss of contrast
N.
false
O.
selenium
P.
indication of radiation absorbed by the imaging plate
Q.
data acquisition
R.
decreases contrast and increases grays
S.
true
T.
Standards resolution IPS
Type the Answer that corresponds to the displayed Question.
incorrect
21.
digital images are less sensitive to scattered and background radiation
incorrect
22.
computerized digital images consist of a _____ of picture elements, each with a video display value or gray shade
incorrect
23.
The flat-panel TFT digital detector uses complex and sophisticated electronic circuitry to read out the electrical charges produced and stored in the matrix array.
incorrect
24.
the LUT is selected by the operator when a procedure is entered at the console
incorrect
25.
in digital imaging the limiting factor in spatial resolution is the
incorrect
26.
A(n) ____ indicator is a numerical parameter used to monitor the radiation exposure to the IP in CR Imaging
incorrect
27.
In the past, gas lasers such as a helium-neon laser were used, however, current CR readers use solid state laser diodes that emit a red laser beam having wavelengths of about 670-690nm
incorrect
28.
When the electron is in the F Center it is at this point when the electrons are spatially distributed and create a _____ image
Type the Question that corresponds to the displayed Answer.
incorrect
29.
Immediate emission of light
incorrect
30.
Delayed emission of light