equipment

        Help!  

Question
Answer
all of the following are associated with the anode except: A. the line focus principal, B. the heel effect C. the focal track. D. therminic emission   D therminic emission  
🗑
the type of x ray tuce designed to turn on an off rapidly, providing multiple short, percise exposures, is   grid controlled  
🗑
name two sricut devices operated on the principal of self induction   autotransrormer, choke coil  
🗑
if esposure factors of 85 kVp, 400 mA, and 12 ms yeils an output exposure of 150 mR, what is the milliroentgens per milliampere-seconds (mR/mAs)   400mAx12ms=4.8 mAs 150mR/4.8mAs=31.25 mR/mAs  
🗑
if a high voltage transformer has 100 primary turns and 50,000 secondary turns and is supplied by 220 v and 100 A, what are the secondary voltage and current   (Vs/Vp)=(Ns/Np) (Ns/Np)=(Ip/Is) (x/200)=(50,000/100) x=11,000,000 (110 kVp) (50,000/100)=(100/x) 50,000=10,000 2=0.2 A(200mA)  
🗑
when using a smaller feild in a dual-feild image intensifier   the image is magnified  
🗑
the electron cloud within the x ray tube is the product of a process called   thermonic emission  
🗑
name something that causes pitting, or many small surface melts, of the anode's focal track   repeated, frequent overloading  
🗑
which of the following woudl pose the least hazard to a particualr anode A. 1.3 mm focal spot, 92 kVp, 1.5 mAs B. 0.6 mm focal spot, 80 kVp, 3 mAs C. 1.2 mm, 70 kv, 6 ma D. 0.6, 60 kv, 12 mAs   A. 1.3 mm focal spot, 92 kVp, 1.5 mAs  
🗑
congruence of the x ray beam with the light feild is tested using   radiopaque objects  
🗑
if the primary coil of a high voltage transformer is supplied by 220 V and has 400 turns and the secondary coil has 100,000 turns, what is the voltage induced in the secondary coil   (Vs/Vp)=(Ns/Np) (Ns/Np)=(Ip/Is) (x/220)=(100,000/400) 400x=22,000,000 x=55,000 V 55Kv  
🗑
name two advantages to a capacitor discharge mobile x ray equipment   compact size and light weight  
🗑
name the system that is a component of the secobdary, or high voltage, side of the x ray circut   recitification system  
🗑
what part of the x ray tube converts electrical enerfy to mechanical energy   motor  
🗑
a slit camera is used to measure what two things   focal spot size and spatial resoultion  
🗑
in what modality woudl a cassette front with very low absorption properties be especially important   mammography  
🗑
name two things that woudl help improve the spatial resolution of imate intensified images   a very thin coating of cesium iodide on the input phosphor and a smaller diameter input screen  
🗑
the advantages of colliamtior over apeture diaphragms and flare cones include (2)   a variety of feild sizes available and more efficent beam restriction  
🗑
during which type of radiation does an electron approaching a positive nuclesr charger changes direction and loses an electron   Bremsstrahlung  
🗑
the voltage ripple assicated with a three phase, six pulse recitified generator is about   13%  
🗑
the device that recieves the remnant beam, converts it into light, and then increases the brigntness of that light is the   image intensifier  
🗑
a high speed electron entering the tungsten targes is affracted tot he positice nucleus of a tungsten atom, and in the process is decelerated. This results in what type of radtiation   bremsstrahlung  
🗑
name the device that is used in digital fluoroscopy, replacing the image intensifier's television camera tube   charged-coupled device  
🗑
a three phase timer can be tested for accuracy using a synchronous spinning top. The resulting image looks like   solid arc, witht he angle (in degrees) representative of the exposure time  
🗑
in ehich type of equipment dies kilovoltage decreasing during the actual length of the exposure   condenser-discharged mobile equipment  
🗑
star and wye configurations are related to   three-phase transformers  
🗑
what is the decive that directs the light emitted from the ii to various viewing and imaging apparatus   beam splitter  
🗑
as electrons impinge on the target surface, less than 1%V of their kinetic energy is changed to   x ray  
🗑
what part of the x ray tube contributes to inherient filtration   x ray tube glass envelope  
🗑
a quality control (QC) program includes checks on thich of the following radiographic equipment: A. reproducibility B. linerality C. positive beam limitation/automatic collimation   all  
🗑
characteristics of x ray phonont include what two   penetrating effects on all matter an ionizing effect on air  
🗑
name the three x ray circut devices that are located between the incoming power supply and the primary coil of the high voltage transformer   the timer, kv meter, and auto transformer  
🗑
what system functions to compensate for changing patitnet/part thichkness during fluoro procedures   ABC  
🗑
name two disadvantages of miving grids over stationary grids   prohibit the use of very short exposure times & increase patient doseq  
🗑
capacitor-discharge mobile x ray units are capacitors to power the   tube  
🗑
the x ray tube in a CT imaging sustes is most likelu to be assiciated with   a pulsed x ray beam  
🗑
name two conditiond that contrubute to x ray tube famage include   lengthly anode rotation & exposures to a cold anode  
🗑
name two pieces of information that is necessary to determinr the max safe kv using the approporite x ray tube rating chart   milliamperage and exposure time & folca spot size  
🗑
a spinning to device can be sued to evaluate (2)   timer accuracy and recitifier failure  
🗑
a decive used to ensure reproducibible radiographs, regardless of tissue density variations   phototimer  
🗑
the device used to change alternating current to ujnidirectional current is   a solid state diode  
🗑
th maintain image clarity in a image intensifier system, the path of th electron flow from the photocathode to the output phosphor is controlled by   electrostatic lenses  
🗑
deposition of vaporized tungsten on the inner surface of the x ray tube glass window acts as what   additional filtration  
🗑
design characteristics of x ray tube targets that determine heat capacity include the A. rotation of the anode B. diameter of the anode C. size of the focal spot   all  
🗑
what term describes the amount of electric charge flowing per second   resistance  
🗑
which of the following is the correct formula for determining heat units for a three phase 12 pulse x ray machine a. kvpxmasxtime b. mAxkVpxmAs c. mAxtimexkVpx1.41   c. mAxtimexkVpx1.41  
🗑
which part of an induction motor is located within the x ray tube glass envelope   rotor  
🗑
which part of an induction morot is locate outside the x ray tube glass envelope   stator  
🗑
capacitor discahge mibile x ray units 1. use grid controlled x ray tube 2. are typically charged before the day's work 3. provide a direct current output   1 & 3  
🗑
advantages of battery powered mobile x ray units include theri   ability to store a large quantity of energy and ability to store energy for extendeed periods of time  
🗑
circut devices that permit electrons to flow in only one direction are   solid state diodes  
🗑
if 92 kV and 15 mAs were sued for a particualr abdominal exposure with single phase equipment what milliampere seconds value would be required to produce a similar radiograph with three phase 12 pulse equipmentq   7.5 (look this up # 94)  
🗑
which of the following devices is used to control voltage by varing resistance   Rheostat  
🗑
which of the following formulas would the radiographer use to determine the total number of heat units produiced with a given exposure using three phase, six pulse equipment A.mAXtimeXkVP B mA *time*kVP*3.0 c. mA*time*kVp*1.35   c. mA*time*kVp*1.35  
🗑
with three phase equipment the voltage actoss the x ray tube 1. drops to zero every 180 degrees 2. is 87% to 96 % of the max value 3. is at nearly constant potential   2 & 3 only  
🗑
raduigraphers from a particualr single-pahse full wave recitified x ray unit were overexposed, using known correct exposures. A spinning top test was prefoemed at 200 mA, 0.05 s, and 70 kVp, and 8 dots were seen on the finished film. What was incorrect   the 0.05 s station in inaccurate  
🗑
accurate operation of the AEC device depends on 1. the thickness and density of the object 2. positioning of the object with respect to the photocell 3. beam restriction   2 & 3  
🗑
the II input phosphor generally is composed of   cesium iodide  
🗑
the device used to test the accuracy of the x ray timer is the   spinning top  
🗑
which of the following statements regarding dual x ray absorptry is (are )true 1. It is a low dose procedure 2. two x ray photon energies are used 3. photon attenuation by bone is calculated   all  
🗑


   

Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
 
To hide a column, click on the column name.
 
To hide the entire table, click on the "Hide All" button.
 
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
 
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.

 
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how
Created by: amanda.clark