When natural light is used to satisfy the minimum light requirements for habitable rooms, the aggregate glazing area shall be a minimum of _ of the floor area. | show 🗑
|
||||
show | 0.04-R303.1
🗑
|
||||
show | 0.05-R309.5
🗑
|
||||
show | 6-R303.1
🗑
|
||||
show 🗑
|
|||||
show | 7 ft-R304.3
🗑
|
||||
Other than in a kitchen, what is the minimum permitted horizontal dimension of any habitable room? | show 🗑
|
||||
show | 7 ft 0 in-R305.1
🗑
|
||||
Ceilings in portions of basements without habitable spaces shall have a minimum ceiling height of _ from the finished floor to beams, ducts; or other obstructions. | show 🗑
|
||||
A minimum clearance of _ shall be provided in front of a water closet. | show 🗑
|
||||
show | 15 in-R307.1
🗑
|
||||
show | 72 in-R307.2
🗑
|
||||
show | 60 F-R303.10
🗑
|
||||
Where located Jess than 5 feet above the walking surface, glazing in a wall adjacent to an outdoor hot tub shall be considered to be installed in a hazardous location unless the glazing is a minimum of _ horizontally from the water’s edge. | show 🗑
|
||||
show | 15 degrees from the vertical-R308.61
🗑
|
||||
show | 0.133333333333333-R308.6.8
🗑
|
||||
A screen used to protect an air exhaust opening that terminates outdoors shall have a minimum opening size of _ inch and a maximum opening size of _ inch. | show 🗑
|
||||
A minimum clearance of _ inches shall be provided in front of the opening to a shower. | show 🗑
|
||||
show | 45732-R308.2
🗑
|
||||
Emergency escape and rescue openings shall be located a maximum distance of _ above the floor where measured to the bottom of the clear opening. | show 🗑
|
||||
Emergency escape and rescue openings, when considered as grade floor openings, shall have a minimum net clear opening of _. | show 🗑
|
||||
For an emergency escape and rescue opening, the minimum net clear opening height dimension shall be _ , and the minimum net clear opening width dimension shall be _. | show 🗑
|
||||
Where an area well is required in conjunction with an escapes and rescue opening, the area well shall have a minimum horizontal area of _ sq. ft. with a minimum horizontal projection and width of _. | show 🗑
|
||||
show | Located at ground level-R309.2
🗑
|
||||
A 6-square-foot skylight pane of laminated glass shall have a minimum _ polyvinyl butyral interlayer where located 14 feet above the walking surface. | show 🗑
|
||||
show | 10-R303.5.1
🗑
|
||||
The illumination source for interior stairways shall be capable of illuminating the treads and landings to a minimum level of _ footcandle(s) as measured at the center of treads and landings. | show 🗑
|
||||
show | 6 ft 8 in-R305.1
🗑
|
||||
A six-square-foot glazed panel adjacent to a door to a storage closet is not required to be safety glazing provided the closet is a maximum of _ in depth. | show 🗑
|
||||
show | 3-in-R308.4.1
🗑
|
||||
Where area wells are provided for escape and rescue openings, area well drainage is not required where the building foundation is supported by Group _ soils. | show 🗑
|
||||
Where lighting outlets are installed in interior stairways, a wall switch shall be pro- vided at each floor level to control the light outlet where the stairway has a minimum of _ risers. | show 🗑
|
||||
A 4-square foot glazed panel installed in an entry door shall have a minimum glazing category classification of Category _ when tested in accordance with CPSC 16 CFR 1201. | show 🗑
|
||||
show | 200-R310.1
🗑
|
||||
An emergency escape and rescue opening may be installed under a deck or porch 5) provided a minimum height of _ inches and minimum width of _ inches are maintained to a yard or court. | show 🗑
|
||||
show |
🗑
|
Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Created by:
user-1915758