lesson 2: Utility Power
Quiz yourself by thinking what should be in
each of the black spaces below before clicking
on it to display the answer.
Help!
|
|
||||
---|---|---|---|---|---|
? is/are fed into transformers to reduce distribution voltage to the utilization voltage specified by the health care facility. | show 🗑
|
||||
Prior to electrical power deregulation, what two service feeds would health care facilities often have? | show 🗑
|
||||
show | utilizing on-site power generation
🗑
|
||||
show | Manual transfer switches
🗑
|
||||
true/false In a manual transfer utility design, in the event of a failure, a qualified person opens the primary feeder switch and closes the secondary feeder switch to provide normal utility power to the facility. | show 🗑
|
||||
show | line side
🗑
|
||||
show | the entire load
🗑
|
||||
In a two-service system that employs two distribution feeders and two utility transformers, how many of the transformers’ secondary sides are provided with a disconnect? | show 🗑
|
||||
Double-ended switchgear electrically divides the load into two distinct sections through the use of ? . | show 🗑
|
||||
During normal operation of double-ended switchgear, the mains from both utility transformers are ? , and the tie breaker between the two ends of the switchgear is ? . | show 🗑
|
||||
During a utility power outage of the primary service, the main switch on the primary should be opened and the tie breaker in the double-ended switchgear should be closed. The secondary service will now carry how much of the health care facility load? | show 🗑
|
||||
A qualified person should open the main switch of the utility transformer experiencing the outage ? closing the tie breaker to avoid backfeeding the grid with the entire energy of the second energized service. | show 🗑
|
||||
show | keying
this system uses a keys that are captured by the system when a switch is closed. this system requires a key to open and a a key to close both the main switch and the tie-breaker.
🗑
|
||||
show | 2
🗑
|
||||
NFPA 99 and NFPA 110 require certain loads in health care facilities, namely elements of the essential electrical system, to be brought online within ? of a power outage. | show 🗑
|
||||
What must be done for current from different utility feeders to occupy the same service bus without issue? | show 🗑
|
||||
true/false Opening one device on a loop distribution system will adequately deenergize the distribution loop. | show 🗑
|
||||
show | Critical systems, Defined equipment and Life safety systems
🗑
|
||||
show | false
🗑
|
||||
show | false
🗑
|
||||
In the event of a generator overload, NFPA 99 and NFPA 70 allow generating systems to ? . | show 🗑
|
||||
When multiple generators are attached to a common bus, ? is used to ensure each generator is in phase with the others. | show 🗑
|
||||
show | 2
🗑
|
||||
show | Heat distribution, Mounting requirements and Starting systems
🗑
|
||||
Generator fuel is often stored in large underground tanks. This fuel is typically pumped into smaller tanks called ? that are located near the generators. | show 🗑
|
||||
Day tanks use ? to alert personnel that a fuel pump is malfunctioning and is no longer pumping fuel from the storage tank. | show 🗑
|
||||
Day tanks use ? to activate the main storage fuel pump to fill the day tank. | show 🗑
|
||||
show | high-level limit sensors
🗑
|
||||
If the fuel pump or level sensors are malfunctioning, day tanks use ? to signal personnel that the tank is about to overflow. | show 🗑
|
||||
Approximately ? of the energy released by burning fuel is converted into electrical energy. | show 🗑
|
||||
show | false
it will not impact the performance of the generator due to the malfunction of an exhaust gas heat exchanger
🗑
|
||||
show | electric pumps
🗑
|
||||
show | true
coolant degrades over time, which can cause scale deposits to build up on the radiator core, severely limiting the core's ability to exchange heat with the surrounding air.
🗑
|
||||
What is the most likely cause for a generator start up failure? | show 🗑
|
||||
show | block heaters
🗑
|
||||
show | nickel cadmium batteries
🗑
|
||||
NFPA 99 requires generator accessories such as battery charging equipment to be installed on the ? branch of the essential electrical system. | show 🗑
|
||||
When batteries have reached the end of life as determined by the manufacturer, or when they are not testing to manufacturer’s specifications, they should be ? . | show 🗑
|
||||
In the past, during high demand periods, power companies would offer health care facilities with self-generation capabilities a reduction in rates if the facility would generate power during these high demand periods. This practice is known as ? . | show 🗑
|
||||
show | The cost of fuel, The cost of generator wear and tear, The price of utility power
🗑
|
||||
The United States Environmental Protection Agency (EPA) has expressed concern about peak shaving because of ? . | show 🗑
|
||||
Because self-generation for non-essential loads is not required to be online within 10 seconds after an outage, ? have become an attractive alternative to reciprocating engines. | show 🗑
|
||||
Turbine engines have much less vibration than reciprocating engines because ? . | show 🗑
|
||||
show | a lower
🗑
|
||||
Gas turbine generators can be a good choice for on-site power generation because ? . | show 🗑
|
Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Created by:
Yusosweet1