Busy. Please wait.
Log in with Clever
or

show password
Forgot Password?

Don't have an account?  Sign up 
Sign up using Clever
or

Username is available taken
show password


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
Your email address is only used to allow you to reset your password. See our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.

Chem 105 lab final

Quiz yourself by thinking what should be in each of the black spaces below before clicking on it to display the answer.
        Help!  

Term
Definition
anayltical balance precision   0.001g`  
🗑
top loading balance precision   0.1g  
🗑
procedure for anayltical balance   close door, empty pan. tare, place object on pan, close door, wait for star, record to 0.001g  
🗑
procedure for top loading balance   place empty weighing container on balance pan, tare to obtain zero reading. carefully add chemical to container. read mass to 0.1g once units stable  
🗑
buret sig fig   0.1mL  
🗑
how to clean a buret   stored with distilled water.remove water, if no droplets form its clean, if not wash with detergent  
🗑
how to fill buret   rinse 2-3 times with liquid to be contained. drain through tip, make sure to rotate so that liquid goes all around inside. then fill slightly above 0 mark. open stopcock, drain to waste beaker to fill tip. no bubbles.  
🗑
how to use buret   wait 15s for liquid to settle. buret should be read to 2 decimal points! once done tranfering, close stopcock, take final buret reading.  
🗑
hwo to use litmus paper   take glass stirring rod and dip into solution. touch this to litmus paper  
🗑
red litmus turned blue   basic  
🗑
blue litmus turns red   acidic  
🗑
what is decanting   seperating ppt from supernatant.  
🗑
what is washing ppt   add small amount dionized water, stir with stirring rod, centrifuge and decant  
🗑
glassware for holding/transferring   beaker, grad cylinder, Erlenmeyer, graduated pipettes  
🗑
glassware for measuring/tranferring   volumentric flask, volumentric flask, burettes  
🗑
percent yield   (moles/moles) obtianed///// (moles/mass) product expected *100%  
🗑
how to use spectrometer   make sure correct wavelength. empty cuvet set 0% transmittance. deionized water cuvet,set 100% transmittance. remove. place sample in cuvet, record value.  
🗑
What is volumetric flas used for?   making a solution whose concentration (eg. molarity) must be known to high precision.  
🗑
precision of volumetric flask   4 sig figs  
🗑
pipette use   transfer liquid of known amount  
🗑
volumetric pippete   deliver fixed amount  
🗑
measuring pipette   calibrated so that any volume up to max can be delivered  
🗑
volumetric pipette precision   2dp  
🗑
volumetric pipette procedure   draw liquid to calibration mark, remove suction unit, and place finger.  
🗑
which pipettes can be blown out?   frosted tip  
🗑
reaction rate depends on what factors?   1. concentration of the reactants 2.temperature at which reaction occurs 3. pressure of a catalyst  
🗑
zero order reaction   1. straight line of [A] vs time 2. slope of best fit equals neg rate constant(-k)  
🗑
first order reaction   1. straight line of ln[A] vs time 2. slope of best fit equals neg rate constant (-k)  
🗑
second order reaction   1. straight line of 1/[A] vs time 2. slope of best fit equals pos rate constant (k)  
🗑
vitamin c, ascorbic acid is a ?   acid, proton donor  
🗑
what is an endpoint   point at which the colour of the indicator just changes colour.  
🗑
why water is slightly acidic?   dissolved CO2  
🗑
phenophalin changes from clear to pink when?   presence of basic solution  
🗑
how to use pH meter?   raise electrode out of storage buffer. rinse dh20, and kimwipe. press cal, yes. place into standard pH 7, when ready light appears, yes, rinse kimwipe. same for 4.00 pH soln. place into unknown. done, place electrode back storage buffer  
🗑
What is electrochemistry   study of the relationship between chemical change and electrical work.  
🗑
electric current   when a charged particle moves, called electrical current.  
🗑
oxidation   chemical loses electrons  
🗑
reduction   chemical gains electrons  
🗑
lab 1   mg ribbon with water and HCl to form H2 gas  
🗑
lab 2   excess of sodium hypochlorite (bleach) to solution of coloring agent.  
🗑
lab 3   titrimetry. -method for determining quantities. standardization of NaOH. fill buret with naoh , erlenmeyer has khp and phenophalin. same with ascorbic acid .  
🗑
what is the primary standard in lab 3?   KHP  
🗑
what is standardization?   process of using a standard to find the precise concentration of another solution .  
🗑
lab 5a   buret has NaNO3 and is adding to K2CrO4.  
🗑
lab 5b   Zn/Sn anode, Cu/Ag cathode.  
🗑
units rate constant 0 order   M/S  
🗑
units rate constant 1st order   s-1  
🗑
units rate constant 2nd order   m-1s-1  
🗑


   

Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
 
To hide a column, click on the column name.
 
To hide the entire table, click on the "Hide All" button.
 
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
 
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.

 
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how
Created by: abc273
Popular Chemistry sets