Stack #132568
Quiz yourself by thinking what should be in
each of the black spaces below before clicking
on it to display the answer.
Help!
|
|
||||
|---|---|---|---|---|---|
| IQ Prereq #1 | Minimum IAQ Performance ASHRAE 62.1 - 2004
🗑
|
||||
| IQ Prereq #2 Environmental Tobacco Smoke Control | Prohibit Smoking; Designated smoking areas 25' from openables and intakes; Continuously exhaust interior areas with 1 Pa neg pressure and 5 Pa avg; measure pressure every 10 sec for 15 min; impermeable deck to deck partitions
🗑
|
||||
| IQ Prereq #2 Continued | Residential; Seal all penetrations in walls, ceilings and floors ; Weather strip all doors leading into common hallways.; ANSI/ASTM - E779-03 Air Leakage Rate. Calif 2001 energy standards.
🗑
|
||||
| IQ Credit #1 OA Monitoring | Alarm when OA below 10% design; Monitor CO2 3'6" AFF
🗑
|
||||
| IQ Credit #2 Increased Ventilation | Increase OA by 30%
🗑
|
||||
| IQ Credit #3.1 Construction IAQ Plan | SMACNA IAQ Guidelines ; protect on site material from water damage; MERV 8 filters at each return air grille; ASHRAE 52.2
🗑
|
||||
| IQ Credit #3.2 IAQ Plan before Occupancy | Building Flush Out 14,000 ft3 per sf maintaining 60 deg 60% RH; or 3500 ft3 OA and ventilate 3 hours per day before occupancy at .3 cfm per sf until 14000 ft3 achieved; Air Quality Testing per EPA.
🗑
|
||||
| IQ Credit #4.1 Low Emitting Materials, Adhesives & Sealants | SCAQMD Rule 1168; Aerosol Adhesives; GS-36
🗑
|
||||
| IQ Credit #4.2 Low Emitting Materials, Paint & Coatings | GS-11; GC-030; SCAQMD Rule 1113
🗑
|
||||
| IQ Credit #4.3 Low Emitting Materials, Carpets | Green Label
🗑
|
||||
| IQ Credit #4.4 Low Emitting Materials , Composite Wood & Agrifiber | No added urea-formaldehyde
🗑
|
||||
| IQ Credit #5 Indoor Chemical & Pollutant Source Control | 6' rugs at all entrances; Exhaust rooms with fumes; MERV 13 filters; ASHRAE 52.2-1999
🗑
|
||||
| IQ Credit #6.1 Controllability of Systems Lighting | provide lighting controls for 90% of occupants.
🗑
|
||||
| IQ Credit #6.2 Controllability of Systems, Thermal Comfort | HVAC controls for 50% occupants; Operable Windows; ASHRAE 62.1-2204 & ASHRAE 55-2004
🗑
|
||||
| IQ Credit #7.1 Thermal Comfort, Design | ASHRAE 55-2004
🗑
|
||||
| IQ Credit #7.2 Thermal Comfort, Verification | Thermal survey within 6-18 months; agree to make changes when 20% complain; ASHRAE 55-2004
🗑
|
||||
| IQ Credit #8.1 Daylight & Views 75% | Minimum glazing 2% for 75% spaces
🗑
|
||||
| IQ Credit #8.2 Daylight & Views 90% | Provide windows between 2'6" - 7'6" aff for 90% occupants
🗑
|
||||
| Innovation in Design #1-14 | Submit in writing; Intent, Req for compliance; Required Submittals; Design Approach
🗑
|
Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Created by:
bobcaine