Save
Busy. Please wait.
Log in with Clever
or

show password
Forgot Password?

Don't have an account?  Sign up 
Sign up using Clever
or

Username is available taken
show password


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
Your email address is only used to allow you to reset your password. See our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.
focusNode
Didn't know it?
click below
 
Knew it?
click below
Don't Know
Remaining cards (0)
Know
0:00
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

electricitycity

Protection and control devices

TermDefinition
Overload Перегрузка. Operating conditions in an electrically undamaged circuit which cause an over-current.
Short-circuit The accidental or intentional connection, by a relatively low resistance or impedance, of two or more points in a circuit which are normally at different voltages.
Residual current (I∆) Дифференциальный ток. It is the vectorial sum of the currents flowing in the main circuit of the circuit_breaker.
Rated operational voltage (Ue) Номинальное рабочее напряжение. voltage which determines the application of the equipment. Ui>Ue
Rated insulation voltage (Ui ) Номинальное импульсное выдерживаемое напряжение. voltage to which dielectric tests voltage and creepage distances are referred. Ui>Ue
Rated impulse withstand voltage (Uimp ) The peak value of an impulse voltage of prescribed form and polarity which the equipment is capable of withstanding without failure under specified conditions of test.
Rated frequency The supply frequency for which an equipment is designed and to which the other characteristic values correspond.
Rated residual operating current (I∆n ) Номинальный отключающий диф.ток. It is the r.m.s. value of a sinusoidal residual operating current at which the CBR shall operate under specified conditions.
r.m.s. Root Mean Square среднеквадратичное значение
Rated breaking capacity Номинальный отключающий ток. the equipment can satisfactorily break, under specified breaking conditions
Rated making capacity Номинальный включающий ток. equipment can satisfactorily make under specified making conditions.
Rated uninterrupted current (In ) circuit-breaker can carry during uninterrupted service
Rated ultimate short-circuit breaking capacity (Icu ) Номинальная предельная отключающая способность. maximum short-circuit current value which the circuit-breaker can break twice (open-time-open-close), at the corresponding rated operational voltage.
Rated service short-circuit breaking capacity (Ics) Номинальная рабочая отключающая способность. short-circuit current value which the circuit-breaker can break three times (open-time-close.open-time-close.open) at a defined rated operational voltage (Ue) and at a defined power factor (cos f).
Rated short-time withstand current (Icw ) Ном. кратковременно выдерживаемый ток. circuit-breaker shall be able to carry this current during the associated short-time delay ( under prescribed conditions of use and behaviour) in order to ensure discrimination between the circuit-breakers in series.
Rated short-circuit making capacity (Icm ) Номинальная рабочая включающая способность. is the value of short_circuit making capacity assigned at Ue, f , cos f for ac.
Created by: Marina Shvedova
Popular Engineering sets

 

 



Voices

Use these flashcards to help memorize information. Look at the large card and try to recall what is on the other side. Then click the card to flip it. If you knew the answer, click the green Know box. Otherwise, click the red Don't know box.

When you've placed seven or more cards in the Don't know box, click "retry" to try those cards again.

If you've accidentally put the card in the wrong box, just click on the card to take it out of the box.

You can also use your keyboard to move the cards as follows:

If you are logged in to your account, this website will remember which cards you know and don't know so that they are in the same box the next time you log in.

When you need a break, try one of the other activities listed below the flashcards like Matching, Snowman, or Hungry Bug. Although it may feel like you're playing a game, your brain is still making more connections with the information to help you out.

To see how well you know the information, try the Quiz or Test activity.

Pass complete!
"Know" box contains:
Time elapsed:
Retries:
restart all cards