Minimum response time of the automatic exposure control is : time required to energize, Shortest possible exposure time, function to prevent over exposure, protect from excessive heat.   SHORTEST POSSIBLE EXPOSURE TIME  
🗑
Which of following devices operates on self induction: auto transformer, high voltage transformer, choke coil.   AUTO TRANSFORMER, CHOKE COIL  
🗑
the filtering effect of the glass envelope and oil in x ray tube are referred to as?   INHERENT FILTRATION  
🗑
which of following will occur as a result in a decrease in the anode target angle. …less pronounced anode heel effect… decrease effective focal spot size, greater photon intensity towards cathode side of x ray tube…   DECREASE EFFECTIVE EFFECTIVE FOCAL SPOT SIZE, GREATER PHOTON INTENSITY TOWARDS CATHODE SIDE OF X RAY TUBE  
🗑
inadequate collimationg when using aec often results in … under exposed xray… over exposed image, timer not terminating soon enough…   UNDER EXPOSED XRAY  
🗑
The source of electrons within the x ray tube are result of?   Thermionic emission  
🗑
What component of the x ray tube is a graphite disc having a tungsten radium track at its periphery?   ANODE  
🗑
X ray tube life may be extended by using.. low mas high kvp, avoiding lengthy anode rotation, avoiding exposures to cold anode.   ALL THREE  
🗑
Which of the following combinations will have greatest heat loading capability, 17 degree target angle & 1.2 mm actual focal spot, 10 degree target angle & 1.2 mm focal spot, 17 degree target & .6mm focal spot,   10* TARGET ANGLE 1.2 MM FOCAL SPOT  
🗑
what is the relationship between kilovoltage and half value layer? as kv increases half value increases, kv decreases half value decreases, if kv is dbl then kv is dbl, if kv dbled half value is squared.   AS KV INCREASES HALF VALUE INCREASES  
🗑
which of following portions of the x ray circuit is the step down transformer located? high voltage side, filament circuit, rectification system, secondary side.   FILAMENT CIRCUIT  
🗑
With 3 phase equipment, voltage across the x ray tube? 1. drops to zero every 180 *, 2. is 87 to 96% maximum value, 3. nearly constant potential:   87 to 96 and nearly constant  
🗑
The photo electric process is an interaction between?   INNER SHELL ELECTRON  
🗑
Which of following devices converts electrical energy into mechanical energy:   GENERATOR  
🗑
basic function of the phototimer: provide brighter image, restrict field size, terminate exposure when correctly exposed, automatically increase or decrease incoming voltage.   TERMINATE WHEN CORRECTLY EXPOSED  
🗑
If one rectifier were malfunctioning resultant mas would be ¼ of expected, ½ expected, twice expected or four times expected.   ½ EXPECTED  
🗑
Which of following voltage ripples is produced by single phase equipment, 100% voltage ripple, 13% voltage ripple, 3.5% ripple.   100% VOLTAGE RIPPLE  
🗑
Decreased x ray tube output can be attributed to? rough focal track, tungsten deposits on glass envelope, high speed anode rotation.   ROUGH FOCAL TRACK, TUNGSTEN DEPOSITS  
🗑
All of following devices may be located on control panel except, ma meter, kvp selector, timer, filament ammeter   FILAMENT AMMETER  
🗑
as the x ray tube filament ages, it becomes thinner due to evaporation, tungsten is deposited on glass envelope: act as filter, reduce x ray output, result in arcing   ALL ABOVE  
🗑
Target angle will have an effect on 1. severity of the heel effect 2. focal spot size 3. heat load capacity   ALL OF ABOVE  
🗑
which devices controls voltage by varying resistance? auto transformer, high voltage transformer , rheostat,   RHEOSTAT  
🗑
Which must be connected in parallel? Filament ammeter, milliampmeter, voltmeter, rectifier.   VOLTMETER  
🗑
Which of following is characteristics of the x ray tube? target material should have high atomic number and melting point, useful beam emerges from window, cathode assembly should receive high and low voltages:   ALL OF ABOVE  
🗑
The advantage or advantages of collimators over aperture diaphragm 1. variety of field sizes available 2. more efficient beam restriction 3. clean up of scatter radiation   VARIETY OF FIELD SIZES AVAILABLE  
🗑
Dedicated radiographic units are available for 1. chest radiography 2. head radiography 3. mammography   ALL ABOVE  
🗑
All of the following are associated with the anode except for 1. line focus principle 2. heel effect 3. focal track 4. thermionic emission   THERMIONIC EMISSION  
🗑
Which of the following contributes to inherent filtration: 1. xray tube glass envelope 2. x ray tube port window 3. aluminum between tube housing and collimator ONE AND TWO   x-ray tube glass envelope and x ray tube port window  
🗑
Circuit devices that conduct electrons in only one direction are:   RECTIFIERS  
🗑
Double focus x ray tubes have two what?   FILAMENTS, LARGE AND SMALL  
🗑
Several types of exposure timers may be found on x ray equipment, which of following types of timers functions to accurately duplicate radiographic density? a. synchronous b. impulse c. electronic d. phototimer   PHOTOTIMER  
🗑
Circuit devices that conduct electrons in only one direction are:   1. resistors 2. valve tubes 3. solid state diodes  
🗑
In order to be used more efficiently by the x ray tube, alternate current is changed into unidirectional current by the:   RECTIFIER  
🗑
all of the following xray devices r located between incoming power supply and high output voltage transformer except for: timer, kv meter, ma meter, auto transformer:   MA METER  
🗑
Radiation sensitive aec devices are known as automatic beam restrictors, ionization chamber, sensor, backup timer:   IONIZATION CHAMBER  
🗑
Which of following meters will not register until exposure is made: kvp major meter, kvp minor meter, ma meter, line voltage meter:   MA METER  
🗑
Star and Y symbols pertain to :   3 phase transformer  
🗑
Features of x ray tube targets that determine heat capacity? rotation of anode, diameter of anode, size of focal spot:   ALL OF ABOVE  
🗑
The Voltage ripple associated with 3 phase 12 pulse rectifier generator is ABOUT 100% , 32% 13%, or 3%:   is about 3PERCENT  
🗑
exposures less than min response time of aec may be required when : using high ma , using fast film speed combo, examining lg patients or parts:   HIGH MA AND FAST FILM  
🗑
most commonly used types of aec devices are? ion chamber, photo multiplier tube, cathode ray tube:   ION CHAMBER, PHOTO MULTIPLIER TUBE  
🗑
As electrons impinge on target surface more than 99% of kinetic energy is changed to:   HEAT  
🗑
Which of following protects patient from overexposure? circuit breaker, fuse, backup timer, rheostat:   back up timer  
🗑
When the radiographer selects kv on control panel, which device is adjusted?   Auto transformer  
🗑
deliver of lg exposure to cold anode or use of exposure exceeding tube limit results in: increase tube output, cracking of anode, rotor bearing damage:   CRACKING ANODE, ROTOR BEARING DAMAGE  
🗑
Tungsten alloy is the usual choice of target material for radiographic equip b/c? high atomic number: high melting point: dissipate heat:   ALL ABOVE  
🗑
To determine how quickly an xray tube will disburse its heat, a radiographer will use a   anode cooling curve.  
🗑
Which of the following will serve to increase the effective energy of the xray beam? increase in added filtration, increase in voltage increase in milliamperage.   filtration and kvp  
🗑
Operation of the aec device is dependent on? thickness of the object, beam restriction or position.   All of the above  
🗑
Which of the following causes pitting on the anode? Vaporized tungsten on the window, loss of anode rotation, frequent overloading.   LOSS OF ANODE ROTATION  
🗑
RADIO TABLES ARE AVAILABLE IN FIXED OR ROTATING? true or false   false  
🗑
basic x ray circuit divided into main circuit and anode circuit? true or false   false  
🗑
during 3 phase power overall potential difference drops to zero. true or false   false  
🗑
the filament is set in cathode assembly outside of focusing cup: true or false   false  
🗑
electrons in thermionic cloud driven to cathode to anode with 100% efficiency: true or false   false  
🗑
the faster anode rotation the better heat dissipation: True or false   true  
🗑
as the anode target angle increases the primary beam filed size increases: true or false   true  
🗑
according to anode heel effect radiation intensity is greater on anode side:   cathode  
🗑
like cathode anode is comprised of single metal called tungsten: true or false   false  
🗑
the ma control is found between incoming line and exposure switch, auto transformer and timer circuit, exposure switch and step up transformer, incoming line and step down transformer:   INCOMING LINE AND STEP DOWN  
🗑
kvp control is found between incoming line exposure switch, auto transformer timer,exposure switch, incoming line step down transformer:   INCOMING LINE AND EXPOSURE SWITCH  
🗑


   

Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
 
To hide a column, click on the column name.
 
To hide the entire table, click on the "Hide All" button.
 
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
 
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.

 
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how
Created by: srehrauer