Audio Final Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Masker for pure tone stimuli | Narrow band noise |
What is used a a masker for speech stimuli? | Speech noise |
Warble pure Fm is used in what population? | pediactric |
Pulsed tone is used in what population? | adults |
A device capable of vibrating when activated by an electrical signal | transducer |
what separates the scala vestibuli from the scala media? | reissners membrane |
what separated scala media fro scala typmani? | basilar membrane |
Frequecies tested for AC? | 250,500,1000,2000,3000,4000,6000,8000 HZ |
When do you test for half octaves? | more than a 20 db differece between octaves |
Frequencies tested for BC | 250,500,1000,2000,3000, and 4000 |
What does the MODIFIES HUGHSON-WESTLAKE TECHNIQUE consist of? | UP 5, DOWN 10 |
Visual reinforcement Audiometry tests what population? | 6 months to 2 years |
What modifications can be done for V.R.A? | up 10 down 20 |
AIR CONDUCTION TRANSDUCERS test what Hz? | 250-8000 |
AC Db testing? | -10 - 110 Db |
BONE CONDUCTION tests what Hz? | 250-4000Hz |
BC tests for what Db? | -10 to 50-80 Db |
Patients hearing loss is based on what results? | AIR CONDUCTION RESULTS |
AIR CONDUCTION looks at what part of the ear? | whole auditory system |
Bone conduction looks at what part of the ear? | Inner ear |
Normal hearing consists of _______ db or less | 10 |
All thresholds are ____ for normal hearing | 25 Db or less. |
Sensorineural hearing loss occurs in what part of the ear? | inner ear |
Air and bone gap are 10 Db or less,but some threshold are worse that 25 Db. | Sensorineural hearing loss |
Conductive hearing loss occurrs in the outer ear only? | true |
Air bone gaps and BOne conduction for CHL? | greater than 10 db , less than or = to 25 Db |
Air bone gap for MIxed hearing loss? | greater than 10 db and bone conuduction greater than 25 Dbhl |
Conditioned play Audiometry deals with what population? CAN IT BE TESTED BY AB AND BC? | 2-4 YEARS. YES |
Right ear is what color? | RED |
Left ear is what color? | BLUE |
Bone conduction RIGHT UNMASKED | < |
BC Right masked | [ |
BC left unmasked | > |
BC left masked | ] |
AC UNmasked left? | x |
AC UNmasked Right? | o |
Masking is needed when there is a ____ DB difference ( in both ears) in AURAL HEADPHONES | 40 |
Masking is needed for inserts when? | difference of 55-60 db |
Masking is needed for bone conduction when? | difference of 15 or more between the air and bone conduction scores of the ear tested |
What noise is used for AC and BC conduction? | narrow band noise |
Normal hearing loss is between ___ and ___ | 0 and 25 |
Mild hearing loss __ and __? | 26 and 40 |
Moderate hearing loss is between ___ and __? | 41-55 |
Moderate/ severe is between ___ and ___? | 56 and 70 |
Severe is between ___ and ___? | 71 and 90 |
Profound is ? | 71 + |
Bilateral hearing loss is ? | similar results in both ears |
unilateral hearing loss is ? | hearing loss in only one ear |
vibro-tactile means? THEY OCCUR MOSTLY BETWEEN WHAT THRESHOLD? | feeling the vibrations rather than hearing it. 250 AND 500 HZ |
what transducer closes off the ear canal? | supra-aural |
Pure Tone Average.AC? | 500,1000,2000 Hz |
Cross Hearing is? | signal delivered to the test ear is heard in the non test ear. |
Bone conduction hearing is placed on the? What does it stimulate? | mastoid process. BOTH COCHLEA'S |
Interaural Attenuation AC SUPRA-AURAL HEADPHONES | 40dB |
Interaural Attenuation: AC insert earphones | 55 dB |
InterAural Attenuation: BONE CONDUCTION VIBRATOR | 0Db |
oCCLUSION EFFECT happens with what transducer? | supra-aural headphones |
OE values 250 Hz =?? | 20dB OE |
OE values 500 Hz= ?? | 15 OE |
1000 Hz = ___ OE? | 5 dB |
When testing, what Hz do you set it too via the speech channel? | 1000 Hz |
what are spondee words? | two syllable compound words |
Speech recognition threshold should be within ___ of the best pta | 7 |
WHAT IS speech detection threshold? | lowest level patient can JUST detect the speech. ( 5-10 DB LOWER THAN SRT) |
What is MCL? | Most comfortable level= 40-50db |
VOWELS are ____ frequency, ____ intensities | low, high |
CONSONANTS are ____ frequencies, ____ intensities. | high, low |
What is UCL? | uncomfortable loudness = 75-95 dB |
What does Supra-Threshold Recognition ? | evaluates how well a person can hear above SPEECH RECOGNITION THRESHOLD |
What is the plateau method? | used for masking |
What is the best indicator of hearing loss in children? | SRT |
When is the only time you have to mask for SRT? | IF YOU HAD TO MASK FOR AC TESTING |
A speech masker is out in the non test ear 20 db below of the words being presented in the | TEST EAR |
What is an example of a tuning fork test? | Rinne Test |
What does the Rinne test compare? | air conduction to the bone conduction resonses |
How is the Rinne performed? | placing the tuning fork on mastoid and then in front of the ear canal. |
What does the WEBER test? | lateralization/placed on forehead |
If the examiner hears the noise longer than the patient, hearing loss is __________ SCHWABACH | Sensorineural |
If the patient hears it longer, hearing loss is ______ SCHWABACH | CONDUCTIVE |
THe SCHWABACH relies on?? | the examiner having normal hearing |
BING test is based on the | occlusion effect |